×

Partner Login

Consultant Login

Borri

  • PARTNER LOGIN
  • GlobalGlobal
    • Italiano Italiano
    • Русский Русский
    • Deutsch Deutsch
  • Applications
    • Critical Power.
      • Computer and Peripheral.
      • Small and Medium data center.
      • Large data center.
      • Networks and Servers.
    • Critical Power.
      • Industrial controls and
        process automation
        .
      • Medical equipment.
      • Building automation.
      • Emergency and safety systems.
    • Industrial Power.
      • Oil & Gas.
      • Power generation
        and water treatment
        .
      • Power transmission & distribution.
      • Marine.
      • Railway.
      • Chemical, Mining and Metallurgy.
      • Process Industry.
    • Renewable Power.
      • Photovoltaic systems.
      • Hybrid energy
        production systems
        .
      • Micro grids.
      • Grid regulation.
  • Products
    • Critical Power:
      • Critical Power 1 Phase
        for ICT
        .
      • Critical Power 3 Phase
        for ICT
        .
      • Critical Power 3 Phase
        for industry and service
        .
      • Data Center solutions.
        • UPSaver 3vo.
    • Industrial Power.
    • Renewable Power.
  • Service
    • Planning, installation, commissioning.
    • Maintenance.
      • Data centers.
      • Critical Power.
      • Industrial Power.
      • Renewable Power.
    • Analytical tests.
    • Battery tests.
    • Repair & spare parts.
    • Training.
    • Remote monitoring.
  • News
  • Download
  • Company
    • Borri 90 years
    • About Us
    • Sustainability
    • Organizational Model and Ethics line
    • Quality & Certifications
    • Careers
  • Contacts
  • Home
  • News
  • Products
  • STS in data centres

STS in data centres

STS in data centres

by Borri spa / Thursday, 28 January 2021 / Published in Products
STS essentials for data centre applications

STS essentials

A Static Transfer Switch, or STS as it is commonly referred to, can be defined as an AC/AC solid-state converter. It supplies the output with one of two input lines where the AC/AC conversion is performed by a pair of Silicon Controlled Rectifiers (or SCRs). Functionally an STS implements a Single Pole Dual Throw switch of a static kind, as opposed to an Automatic Transfer Switch (ATS), where the switches are electro-mechanical.

Besides inherently higher reliability due to the use of solid-state components as opposed to electro-mechanical ones, the main difference between STSs and ATSs is a shorter transfer time: 2-3 ms against 100 ms or more. Therefore, while less expensive ATSs are commonly used as the source changeover, i.e. between commercial utilities and generator sets, STSs are the only option to seamlessly transfer power between power feeds downstream of the UPS system.

STS Ampere rating

Like electro-mechanical switches, STS are current rated systems. The main defining figure is how many Amperes they can indefinitely let flow and switch. Although STSs also have a voltage rating, which is related to the components’ safe operating area, power ratings do not apply and therefore no kVA figure should be used in defining STS requirements.

3  and 4 pole STS

A three-phase STS can be 3- or poles, meaning that the system is featuring three or four wires for each of the two input lines and the output line. The fourth being the neutral wire. 3- pole STSs are used in pure three-phase arrangement, where the neutral wire is not used at all, or when the two sources feeding the STS share a common neutral and there is no need to switch or disconnect it.

On the other hand, four pole STSs must be used whenever a neutral disconnection is required. Four pole STSs can further be divided in two categories: switched or non-switched neutral, meaning that the neutral wire is equipped or not with the relevant SCR pair.

As far as two 4-wire independent sources are concerned, 4-switched-pole arrangement should be used, in order to prevent the two independent neutrals to be connected together, which is the case whenever a 4-non-switched-pole STS operates normally, with both its 4-pole input switches closed. As an example, an STS basic requirement should read as: 630 A, 400 V, 4-switched poles.

STS in data centres

Despite STSs being general purpose equipment, they are far more popular within data centres (DC) than in any other industry. The reason being is the massive deployment of redundant schemes that the DC market has experienced over the past decade. In addition to the typical A-B dual supply, different redundancy schemes have been more recently developed following the constant trend for both cost and carbon footprint reduction. Distributed redundancy 3 out of 4 and failover schemes to name a few, have therefore become more and more popular due to the benefit of a lower UPS power deployment.

In the distributed redundancy 3 out of 4 arrangement, ’1.5N’ UPS power is required, where ‘N’ is the total IT required power, against the most resilient, but quite expensive ‘2N’ scheme. Even less power is deployed in the failover arrangement, that is equivalent to a proper ‘N+1’ scheme, where one UPS acts as the backup power source for a set of same size UPS units feeding an overall ‘N’ design. In both schemes STS units are required to distribute the UPS power to the IT loads, as to maximize availability.

Single phase STSs are widely used at PDU level, that is in the power section of the racks, to provide both feeds of a redundant arrangement to non-dual SMPS (Switch Mode Power Supply) servers or network equipment. In this application, SCR-based STSs are usually preferred as opposed to relay-based units, due to the former’s superior switching performance and durability.

For more information on Borri 1-phase and 3-phase STSs please download our brochure or visit our  STS 16-32 and STS 300 web pages.

For further inquiries you can email us at info@borri.it

What you can read next

Peak Shaving UPS and smart grids
Peak shaving and smart grids: the new frontier of UPS systems
Case study CERN: Borri protects the particle accelerator
Battery sizing Borri UPS
Battery sizing for Borri Critical Power UPS

Search

Recent Posts

  • Borri UPS's at High Tech Campus in Villach, Austria

    Borri UPS’s at the High Tech Campus in Villach, Austria

    UPS systems play a crucial role in research and...
  • Borri UPS for healthcare applications

    Borri secures smooth process in one of the largest hospitals in Varna, Bulgaria

    As the third-largest city and major seaport in ...
  • Hydrogen Eletrolysis DC Rectifiers

    Providing efficient power for middle-market green hydrogen electrolysis

    In a world increasingly conscious of its enviro...
  • UPS and STS redundancy schemes

    How UPS and STS redundancy schemes can increase availability

    Redundancy is the most used and effective way t...
  • UPS for airport applications

    Enhanced safety and efficiency for a major airport in Spain.

    Earlier this year Borri and Sinergia S.L., offi...

Archives

  • February 2025
  • September 2024
  • June 2024
  • January 2023
  • November 2022
  • April 2022
  • December 2021
  • July 2021
  • March 2021
  • January 2021
  • November 2020
  • May 2020
  • February 2020
  • January 2020
  • October 2019
  • August 2019
  • May 2019
  • November 2018
  • October 2018
  • July 2018
  • February 2018
  • October 2017
  • May 2017
  • March 2017
  • February 2017
  • January 2017
  • December 2016
  • September 2015
  • November 2014
  • September 2014
  • April 2014
  • February 2014
  • January 2014

Categories

  • Case study
  • Corporate
  • Events
  • Exhibitions
  • Products

Applications

  • Critical Power UPS for ICT & data center
  • Critical Power UPS for industry & service
  • Industrial Power
  • Renewable Power

Products

  • Critical Power 1 Phase for ICT
  • Critical Power 3 Phase for ICT
  • Critical Power 3 Phase
    for industry and service
  • UPSaver System
  • Industrial Power
  • Renewable Power

Services

  • Planning, installation, commissioning
  • Maintenance
  • Analytical tests
  • Battery tests
  • Repair & spare parts
  • Training
  • Remote monitoring
  • Privacy Policy
  • Cookie Policy
  • GET SOCIAL

Borri S.p.A. • A Sole Shareholder Company • P.IVA 03471720965
R.I. Arezzo e C.F. 10030570153 • R.E.A. Arezzo 135781 • Cap.Soc.Euro 793.341 int.vers.

TOP



Your request could not be saved. Please try again.



Thank you for your request.

Download the Article

Fill in the form and download the Article


We use Sendinblue as our marketing platform. By Clicking below to submit this form, you acknowledge that the information you provided will be transferred to Sendinblue for processing in accordance with their terms of use





La tua richiesta non può essere elaborata, prova di nuovo.



Grazie per il tuo download.

Scarica l’articolo

Compila il form e scarica subito l’articolo


We use Sendinblue as our marketing platform. By Clicking below to submit this form, you acknowledge that the information you provided will be transferred to Sendinblue for processing in accordance with their terms of use