Single-phase and three-phase output UPS for small and medium data centers, servers, network and telecom devices, safety and emergency systems, building automation, medical equipment.
Rating (kVA) | 10 | 15 | 20 |
Nominal power (kW) | 9 | 13.5 | 18 |
UPS dimensions WxDxH (mm) | 450x670x1200 | ||
UPS weight (kg) | 100 | 110 | 110 |
UPS weight with internal battery (kg) | 247 | 257 | 257 |
External battery module dimensions WxDxH (mm) |
500x640x1200 | ||
Battery configuration | Internal or external, 360 to 372 cells, VRLA (other options) | ||
Max. autonomy with int. battery 70% load (min) | 32 | 19 | 12 |
B8031FXS (10-15-20 kVA) | B8033FXS (10-15-20 kVA) | |
Connection type | Hardwired 4w (rectifier), 2w (bypass) | Hardwired 4w |
Nominal voltage | 400 Vac 3-phase with neutral (rectifier) 220/230/240 Vac 1-phase (bypass) |
400 Vac 3-phase with neutral (rectifier) 380/400/415 Vac 3-phase with neutral (bypass) |
Voltage tolerance | ||
Frequency and range | 50/60 Hz, 45 to 65 Hz | |
Power factor | 0.99 | |
Current distortion (THDi) | <4% |
B8031FXS (10-15-20 kVA) | B8033FXS (10-15-20 kVA) | |
Connection type | Hardwired 2w | Hardwired 4w |
Nominal voltage | 220/230/240 Vac 1-phase | 380/400/415 Vac 3-phase with neutral |
Frequency | 50/60 Hz | |
Voltage regulation | Static ±1%; dynamic: IEC EN 62040-3 Class 1 | |
Power factor | Up to 0.9, without power derating | |
Overload capacity | Inverter: 125% for 10 min, 150% for 30 s, >150% for 10 s; bypass: 150% continuous, 1000% for 1 cycle |
|
Efficiency (AC/AC)* | Up to 98% | |
Classification as per IEC EN 62040-3 |
*according to IEC EN 62040-3
Front panel | Graphic display, mimic LED panel and keyboard, local EPO | |
Remote communication | Included: serial RS232 and USB; terminal block for battery breaker auxiliary contact. Optional: input terminal block (remote emergency power off, external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.); SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485), from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software |
|
Optional function extensions | Isolation transformer; transformers/autotransformers for voltage adjustment; external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit, load-sync for single UPS; other options on request |
Protection degree | IP 20 | |
Colour | RAL 7016 | |
Installation layout | 10 cm wall-gap, side by side installation allowed | |
Accessibility | Front and top access, bottom cable entry |
UPS operating temperature range | 0 °C to +40 °C | |
UPS storage temperature range | -10°C to +70 °C | |
Altitude (AMSL) | <1000 m without power reduction, >1000 m with reduction of 0.5% per 100 m | |
Audible noise at 1 m (dBA) | <52 |
Quality assurance, environment, health and safety | ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007 | |
Safety | IEC EN 62040-1 | |
EMC | IEC EN 62040-2 | |
Environmental aspects | IEC EN 62040-4 | |
Test and performance | IEC EN 62040-3 | |
Protection degree | IEC 60529 | |
Marking | CE |