High power modular UPSs UPSaver and UPSaver 3vo deliver unsurpassed performance for large and hyperscale data centres providing the highest level of availability for this power range, lowest power consumption and TCO.
Click here to learn more about the patented Green Conversion technology
Rating (kVA) | 400 | 600 | 800 | 1000 | 1200 | 1400 | 1600 |
N nominal power (kW) | 400 | 600 | 800 | 1000 | 1200 | 1400 | 1600 |
N+1 nominal power (kW) | 200 | 400 | 600 | 800 | 1000 | 1200 | 1400 |
UPS dimensions WxDxH (mm)* |
2350x 970x 2100 |
2950x 970x 2100 |
3900x 970x 2100 |
4500x 970x 2100 |
5100x 970x 2100 |
6800x 970x 2100 |
7400x 970x 2100 |
UPS weight (kg)* | 1660 | 2260 | 2920 | 3590 | 4190 | 4960 | 5560 |
Battery configuration | External 360 to 372 cells, VRLA (other options) |
* referred to distributed battery, distributed static switch, bottom cable entry. For other configurations contact our sales team.
Connection type | Hardwired 4w (rectifier), 4w (bypass) | ||||||
Nominal voltage | 400 Vac 3-phase with neutral (rectifier), 380/400/415 Vac 3-phase with neutral (bypass) | ||||||
Voltage tolerance | -20%, +15% (rectifier); ±10% (bypass) | ||||||
Frequency and range | 50/60 Hz, 45 to 65 Hz | ||||||
Power factor | 0.99 | ||||||
Current distortion | <3% |
Connection type | Hardwired 4w | ||||||
Nominal voltage | 380/400/415 Vac 3-phase with neutral | ||||||
Frequency | 50/60 Hz | ||||||
Voltage regulation (VFI) | Static: ±1%; dynamic: IEC/EN 62040-3 Class 1 |
||||||
Power factor | Any power factor (leading or lagging) up to 1, without power derating | ||||||
Overload capability | Inverter: 125% for 10 min, 150% for 1 min; bypass: 150% continuous, 1000% for 1 cycle |
||||||
AC/AC efficiency** | Up to 99.5% | ||||||
Classification as per IEC/EN 62040-3 |
VFI-SS-111 |
** according to IEC/EN 62040-3.
Front panel | 10” colour touch screen display, 1024x600 pixels | ||||||
Remote communication | Included: serial RS232 and USB; input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.,
external output circuit breaker aux. cont., remote transfer to bypass mode); SPDT contact relay board; ModBus-RTU (RS485);
Optional: ModBus-TCP/IP (Ethernet); ModBus-RTU to PROFIBUS DP adapter |
||||||
Optional function extensions | Isolation transformer; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit;
load-sync for single UPS and load-sync box (2 UPS systems); other options on request |
Protection degree | IP 20 | |||||||
Colour | RAL 9005 | |||||||
Installation layout | Wall, back to back and side by side installation allowed | |||||||
Accessibility | Front and top access, bottom and top cable entry | |||||||
Parallel configuration | Up to 8 UPS, for a total of 12.8 MW |
Operating temperature | 0°C to +40°C | ||||||
Storage temperature | -10°C to +70°C | ||||||
Altitude (AMSL) | < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m | ||||||
Audible noise at 1m (dBA) | <50 (UHE) |
Quality assurance, environment, health and safety |
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 | ||||||
Safety | IEC/EN 62040-1 | ||||||
EMC | IEC/EN 62040-2 | ||||||
Environmental aspects | IEC/EN 62040-4 | ||||||
Test and performance | IEC/EN 62040-3 | ||||||
Protection degree | IEC 60529 | ||||||
Marking | CE |
Rating (kVA) | 670 | 1000 | 1340 | 1670 | 2000 | 2340 | 2670 |
N nominal power (kW) | 670 | 1000 | 1340 | 1670 | 2000 | 2340 | 2670 |
No. of modules | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
UPS dimensions WxDxH (mm)* |
3800x 970x 2150 |
4450x 970x 2150 |
6550x 970x 2150 |
7200x 970x 2150 |
7650x 1200x 2150 |
8800x 1200x 2150 |
(***) |
UPS weight (kg)* | 2140 | 2710 | 4205 | 4775 | 5770 | 6630 | (***) |
Battery configuration | External 360 to 372 cells, VRLA, Li-Ion (other options) |
Connection type | Hardwired 4w (rectifier), 4w (bypass) | ||||||
Nominal voltage | 400 Vac 3-phase with neutral (rectifier), 380/400/415 Vac 3-phase with neutral (bypass) | ||||||
Voltage tolerance | -20%, +15% (rectifier); ±10% (bypass) | ||||||
Frequency and range | 50/60 Hz, 45 to 65 Hz | ||||||
Power factor | 0.99 | ||||||
Current distortion (THDi) | <3% |
Connection type | Hardwired 4w | ||||||
Nominal voltage | 380/400/415 Vac 3-phase with neutral | ||||||
Frequency | 50/60 Hz | ||||||
Voltage regulation | Static: ±1%; dynamic: IEC/EN 62040-3 Class 1 |
||||||
Power factor | Up to 1, with no power derating | ||||||
Overload capability** | Inverter: 105% continuous at 30° C, 125% for 10 min, 150% for 1 min; bypass: 110% continuous, 150% for 1 min, 700% for 100 ms, 1000% for 10 ms |
||||||
AC/AC efficiency | Up to 99% | ||||||
Classification as per IEC/EN 62040-3 |
VFI-SS-11 |
* full option version including top busbar entry module, main switches, hot swap distribution modules. ** conditions apply. *** contact our sales team for confirmation.
Front panel | 10” colour touch screen display, 1024x600 pixels | ||||||
Remote communication | Included: serial RS232; input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.,
external output circuit breaker aux. cont., remote transfer to bypass mode); SPDT contact relay board; ModBus-RTU (RS485);
Optional: ModBus-TCP/IP (Ethernet) |
||||||
Optional features | Isolation transformer; battery cabinets; DC protection cabinets; battery thermal probe; parallel kit;
load-sync for single UPS and load-sync box (2 UPS systems); other options on request |
Protection degree | IP 20 | |||||||
Colour | RAL 9005 | |||||||
Installation layout | Wall, back to back and side by side installation allowed | |||||||
Accessibility | Front and top access, bottom and top cable entry | |||||||
Parallel configuration | Up to 8 UPS, for a total of 21 MW |
Operating temperature | 0°C to +40°C with no power derating | ||||||
Storage temperature | -10°C to +70°C | ||||||
Altitude (AMSL) | < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m | ||||||
Audible noise at 1m (dBA) | <65 |
Quality assurance, environment, health and safety |
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007 | ||||||
Safety | IEC/EN 62040-1 | ||||||
EMC | IEC/EN 62040-2 | ||||||
Environmental aspects | IEC/EN 62040-4; ISO 14025 | ||||||
Test and performance | IEC/EN 62040-3 | ||||||
Protection degree | IEC 60529 | ||||||
Marking | CE |