×

Copernico TT

Applications

  • LV photovoltaic power plants
  • MV/HV photovoltaic power plants
  • Stand alone photovoltaic power plants with energy storage system
  • Grid connected photovoltaic power plants with energy storage system
  • Hybrid power generation station
  • Peak shaving
  • Load balancing
  • Time shifting
  • High reliability

    • Longer time between maintenance activities
    • Reduction of energy production losses due to inverter failure
  • High efficiency

    • Some competitors declare only the maximum efficiency
    • Copernico’s efficiency is measured in the real operating conditions with all the auxiliary circuit connected
  • Low current distortion

    • Competitor’s average values are in the range 3–4%
    • Lower current distortion leads to a general reduction of the energy losses in conductors and transformers
  • Wide MPPT range

    • One of the widest (370Vdc) among inverter manufacturers
    • The energy production of the PV array is maximised
  • High output voltage in TL series (300 Vac)

    • Competitor’s average values 270–280 Vac y
    • Higher voltage = Lower current
    • Smaller AC cables and circuit breakers
  • Simplified installation

    • Single mechanical structure up to 500 kW
    • Space saving thanks to:
    • Small foot-print for all the range
    • Reduced installation clearances
  • Wide range availability of accessories for PV plants

    • Array Monitor (stings boxes)
    • Green Power Guardian (monitoring System)
    • PV sensors to measure environmental temperature, PV panel temperature, solar radiation

Technische Daten

Copernico TT

Rating (kVA) 20 30 50 100
Nominal power (kW) 20 30 50 100
Max PV power (kWp) 24 35 60 120
Dimensions WxHxD (mm) 690x1345x895 800x1900x800
Weight (kg) 475 486 540 905

Input

Maximum voltage 1000 V
MPPT range voltage 450 ÷ 820 V
Maximum current (A) 46 69 115 230
Input protection Isolator PV switch + fuses Isolator PV switch

Output

Nominal voltage 400 V 3-phase with integrated transformer
Frequency 50/60 Hz
Power factor 0.99 Cos Ø depending on grid regulation
Current harmonics (THD) < 2 % @ nominal power and sinusoidal voltage
Output protection Electronic short-circuit protection - fuses - contactor
Maximum efficiency (%) >94.12 >95.51 >95.79 >96.28
European maximum efficiency (%) >93,20 >94,08 >95,04 >95,79
Loss under normal operation (Wh) 1150 1350 2100 3720
Nominal power (BTU) 3900 4600 7200 12700

Connectivity and function extensions

Front panel LCD display, mimic LED panel and keyboard
Remote communication Modbus RS485

System

Protection degree IP 20
Colour RAL 7035
Accessibility Front access

Environmental

Operating temperature -10 °C ÷ +50 °C
Storage temperature -10 °C ÷ +70 °C
Non-condensing relative humidity <95%
Altitude < 1000 m above sea level
Audible noise at 1 meter (dBA) <68

Standards and certifications

Quality assurance, environment, health and safety ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
Safety IEC 62103 - EN 50178
EMC IEC EN 61000-6-2, IEC EN 61000-6-4
Protection degree IEC EN 60529
Marking CE
Your membership cannot be validated.
Your registration was successful.

Newsletter

Subscribe to our newsletter and stay updated

Utilizziamo Brevo come nostra piattaforma di marketing. Cliccando qui sotto per inviare questo modulo, sei consapevole e accetti che le informazioni che hai fornito verranno trasferite a Brevo per il trattamento conformemente alle loro condizioni d'uso

OBEN